Boba Commercial Style, Hardwired, EV Charger with QR Scan & Owner Controlled Payment System
ORDER NOW — SHIPS ON OR BEFORE OCTOBER 26, 2026
Stop losing bookings and customers. EV drivers stay and shop where they can charge.
ONE SYSTEM, ONE APP
Commercial and residential Boba chargers run on the same system and are controlled from the same Boba owner app. Every charger you own shows up in one place — set pricing, monitor usage, and track revenue across all of them, residential and commercial alike.
MORE DURABLE
Same charging power as our residential 48A charger. The difference is durability — heavier-duty commercial construction throughout and a 25' commercial-grade cord, built for constant daily use.
*Currently selling in the USA, Hawaii, Puerto Rico, Alaska, and the US Virgin Islands. For international inquiries, please email info@bobacharge.com
Boba Charge is designed to make charging electric vehicles easy, fast, and more convenient for both users and owners.
What makes it different for customers is the built-in QR code payment system for users. Instead of dealing with apps or complicated setups, EV drivers can simply scan the code with a phone camera, make a payment, and start charging right away. No user app required. The entire transaction takes about 30 seconds.
What makes it different for owners is the Boba Charge owner app that allows you to setup your charger, name it, set your KwH price and monitor all EV charges, sales and electricity usage.
Getting Paid:
Owners set pricing per kilowatt hour
Owners keep 90% of all revenue
BOBA handles financial transactions
Revenue paid out the first of the month - optional, on-demand payouts for a 5% fee
Key Features:
Same system and same owner app as every residential Boba charger
Easy scan → pay → charge system - No EV driver app required
Built for both indoor and outdoor use
Reliable and efficient charging performance
Why It's Useful:
Boba Charge removes the stress of complicated charging systems and makes the whole process simple for both the person charging their EV vehicle and the Boba Charge owner. And most importantly Boba makes you money. Boba is a Business in a Box!
Technical Specifications
- Durability: heavier-duty commercial construction throughout, built for constant daily use
- EV charger class: Level 2
- Heavier-duty commercial construction throughout
- Charging current: 48A fixed. Fully automatic — the charger matches your vehicle.
- Electrical setup: 240V hardwired
- Circuit required: 60A breaker, 6 AWG copper
- Charging cord: 25' commercial-grade
- Charging speed: about 30-44 miles of range per hour, depending on your vehicle
- Charging connector: SAE J1772 (optional NACS/Tesla adapter sold separately)
- Enclosure: NEMA 4 / IP65 — indoor or outdoor, -22°F to 122°F
- No app for EV drivers
- Owner app
- Wifi and Ethernet
- ETL, ENERGY STAR and FCC certified
- 2-year manufacturer warranty with advance replacement
Includes EV charger only. All other accessories are sold separately.
Everything your electrician will ask.
The full electrical picture for the 48A commercial charger.
- Power
- 240V, hardwired — no outlet or plug
- Charging level
- Level 2
- Connector
- SAE J1772 (optional NACS/Tesla adapter sold separately)
- Cable length
- 25 ft commercial-grade
- Output
- Fixed 48A — 11.5 kW
- Circuit required
- 60A breaker, 6 AWG copper
- Charging speed
- About 30-44 miles of range per hour, depending on your vehicle
- Same power as the residential model
- 48A and 11.5 kW, the same charging speed as the residential 48A charger. The difference is durability.
- Construction
- Heavier-duty commercial construction throughout, built for constant daily use
- Cord
- 25 ft commercial-grade, longer and heavier than the residential cord
- Enclosure rating
- NEMA 4 / IP65
- Installation
- Indoor or outdoor rated
- Operating temperature
- -22°F to 122°F
- Certifications
- ETL, ENERGY STAR, FCC
- Warranty
- 2-year manufacturer warranty, with advance replacement
- Guest experience
- QR scan and pay in about 30 seconds. No app and no account for the guest.
- Your share
- You keep 90% of every charge
- Fees
- No processing fees, no subscription, no cellular fees, no monthly fees
- Payouts
- Paid monthly on the 1st. Optional on-demand payout for 5%.
Electrical — 48A commercial charger
More durable
Enclosure and environment
Certifications and warranty
Payment and payouts
Breaker and wire sizes are typical for a standard run. Your electrician confirms the final size for your run length and local code. Install per NEC Article 625 and local codes.
Everything your electrician will ask.
The full electrical picture for the 80A heavy-duty commercial charger.
- Power
- 240V, hardwired — no outlet or plug
- Charging level
- Level 2
- Connector
- SAE J1772 (optional NACS/Tesla adapter sold separately)
- Cable length
- 25 ft commercial-grade
- Output
- Fixed 80A — 19.2 kW
- Circuit required
- 100A two-pole breaker, 3 AWG copper conductors, 8 AWG copper ground
- Charging speed
- About 30-40 miles of range per hour on vehicles that accept 19.2 kW
- What it's for
- Properties charging electric pickups, vans or fleet vehicles overnight — vehicles with very large batteries that can accept 19.2 kW
- Availability
- Special order, minimum 20 units
- Construction
- Heavier-duty commercial construction throughout, built for constant daily use
- Cord
- 25 ft commercial-grade, longer and heavier than the residential cord
- Enclosure rating
- NEMA 4 / IP65
- Installation
- Indoor or outdoor rated
- Operating temperature
- -22°F to 122°F
- Certifications
- ETL, ENERGY STAR, FCC
- Warranty
- 2-year manufacturer warranty, with advance replacement
- Guest experience
- QR scan and pay in about 30 seconds. No app and no account for the guest.
- Your share
- You keep 90% of every charge
- Fees
- No processing fees, no subscription, no cellular fees, no monthly fees
- Payouts
- Paid monthly on the 1st. Optional on-demand payout for 5%.
Electrical — 80A heavy-duty commercial charger
More durable
Enclosure and environment
Certifications and warranty
Payment and payouts
Breaker and wire sizes are typical for a standard run. Your electrician confirms the final size for your run length and local code. Install per NEC Article 625 and local codes.